Flexible Shaft Couplings are extensively used in numerous industrial applications for backlash free transmission of Torque; Speed & Motion from one shaft to another shaft. Flexible Shaft Couplings can adjust itself to misalignment of two shafts connected by it. Misalignment between two shafts causes loss of performance; power; damage to shafts; its bearings; there by generating heat & noise, thus damaging the rotating equipment. Misalignment (displacement) between two shafts can be axial; radial or angular. When motion transmission between two shafts is important, the misalignment should not affect the acceleration, speed or motion of the shaft. Following listed applications thus calls for a torsionally rigid but yet a backlash free Flexible Shaft Coupling.
Applications:
Shaft Encoders; Tachogenerators; Stepper & Synchronous Motors; Rotary Position Transmitters; Damper Drives; Potentiometers & Variacs; etc ...
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 30 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 0 to 5 VDC; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 30 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 1 to 5 VDC; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 30 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 2 to 10 VDC; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 30 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 0 to 10 VDC; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 30 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 4 to 20 mA; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 30 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 0 to 20 mA; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 45 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 0 to 5 VDC; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 45 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 1 to 5 VDC; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation
Sipin 3-Wire 3-Phase Angle Controller (SCR Power Regulator); Main Power Voltage: 200-480 Vac; Normal Rated Current: 45 Amps; Auxiliary Power Source Code: 220 Vac; Input Signal Code: 2 to 10 VDC; Buffering Time Code: Adjustable 1 to 22 Seconds.
Independent adjustment of Max and BIAS
Downward opening front Panel for easy Fuse replacement
VR setting of Max and SFS are installed in the front panel, for easy adjustment
Multi-LED display panel makes the operating indications clear
The Auxiliary Powers (AC1, AC2) are independently controlled for all models
Built-in buffering output adjustment (SFS VR), adjusting Range: 1-22 seconds (Only for the phase control product)
Top & bottom Shielding Covers are designed for safety and easy wiring installation
In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse blow out
Main power is designed for 200-480VAC
Automatic power frequency detection for 50-60 Hz. No need for selection or switch
Automatic detection and display for Power Out-of-Phase, SCR Over Heating, Fuse Blow Out with one set of alarm dry contact output
In cases of SCR Over Heating or Fuse Blow Out, the system output is stopped immediately. Once the malfunction is eliminated and power is restored, the system will buffer the output to prevent the fuse Blow Out
4-20mA, 1-5VDC, 2-l0VDC, 0-20mA, 0-5 VDC, 0-l0VDC, dry contact points, etc. and all control signals are ready to use
Triggering circuit and the main board are designed separately to avoid the main board damage when main circuit malfunctions
Using European detachable control signal connector for easy replacement without the need of re-wiring installation