IEC Industrial Cylindrical Fuses (gL-gG)
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DF Electric Class gG Cylindrical Fuses are used for general full range protection against overloads and short circuits, ideally suitable for protection of cables, power lines and equipments. These fuses are made with superior ceramic tube to withstand high internal pressure and thermal shock that allow a high breaking capacity in a small body construction. The internal melting elements are silver plated in order to avoid aging, thus maintaining optimum electrical characteristics. Contact caps are made with silver plated copper. These Fuses are available in four physical sizes, ampere ratings from 0,5 to 125 A & with rated voltage 400 to 690 Vac. In addition to Fuses without indicator, most ratings / sizes are also available with a blown fuse indicator or Striker Pin. Fuses with Striker Pin can be used in Fuse Holders with Micro Switch for alarm. Meets IEC, EN Standards. All Products are with CE marking.

 
Size : 8 x 31 mm (Ø x L)
Rated Current (A) Catalogue No. Rated Voltage (Vac) Breaking Capacity (kA) Packing Qty
  Without Indicator With Indicator      
0.5 420500 -- 400 20 10/100
1 420501 -- 400 20 10/100
2 420502 420602 400 20 10/100
4 420504 420604 400 20 10/100
6 420506 420606 400 20 10/100
8 420508 420608 400 20 10/100
10 420510 420610 400 20 10/100
12 420512 420612 400 20 10/100
16 420516 420616 400 20 10/100
20 420520 420620 400 20 10/100
*25 420525 420625 400 20 10/100

*Overrating Fuse
 
Size : 10 x 38 mm (Ø x L)
Rated Current (A) Catalogue No. Rated Voltage (Vac) Breaking Capacity (kA) Packing Qty
  Without Indicator With Indicator      
0.5 420000 -- 500 120 10/100
1 420001 -- 500 120 10/100
2 420002 420102 500 120 10/100
4 420004 420104 500 120 10/100
6 420006 420106 500 120 10/100
8 420008 420108 500 120 10/100
10 420010 420110 500 120 10/100
12 420012 420112 500 120 10/100
16 420016 420116 500 120 10/100
20 420020 420120 500 120 10/100
25 420025 420125 500 120 10/100
*32 420032 420132 400 120 10/100
 
Size : 14 x 51 mm (Ø x L)
Rated Current (A) Catalogue No. Rated Voltage (Vac) Breaking Capacity (kA)
  Without Indicator With Indicator    

1

421001

--

690

80

2

421002

421102

690

80

4

421004

421104

690

80

6

421006

421106

690

80

8

421008

421108

690

80

10

421010

421110

690

80

12

421012

421112

690

80

16

421016

421116

690

80

20

421020

421120

690

80

25

421025

421125

690

80

32

421032

421132

500

120

40

421040

421140

500

120

50

421050

421150

400

120

Size : 14 x 51 mm (Ø x L)
Catalogue No. Rated Voltage (Vac) Breaking Capacity
(kA)
Packing Qty.
With
Striker
     

--

--

--

10/50

421202

500

120

10/50

421204

500

120

10/50

421206

500

120

10/50

421208

500

120

10/50

421210

500

120

10/50

421212

500

120

10/50

421216

500

120

10/50

421220

500

120

10/50

421225

500

120

10/50

421232

500

120

10/50

421240

500

120

10/50

421250

400

120

10/50

 
Size : 22 x 58 mm (Ø x L)
Rated Current (A) Catalogue No. Rated Voltage (Vac) Breaking Capacity (kA)
  Without Indicator With Indicator    

2

422002

422102

690

80

4

422004

422104

690

80

6

422006

422106

690

80

8

422008

422108

690

80

10

422010

422110

690

80

12

422012

422112

690

80

16

422016

422116

690

80

20

422020

422120

690

80

25

422025

422125

690

80

32

422032

422132

690

80

40

422040

422140

690

80

50

422050

422150

690

80

63

422063

422163

690

80

80

422080

422180

690

80

100

422000

422100

500

120

125

422015

422115

400

120

Size : 22 x 58 mm (Ø x L)
Catalogue No. Rated Voltage (Vac) Breaking Capacity
(kA)
Packing Qty.
With
Striker
     

--

--

--

10/50

422204

690

80

10/50

422206

690

80

10/50

422208

690

80

10/50

422210

690

80

10/50

422212

690

80

10/50

422216

690

80

10/50

422220

690

80

10/50

422225

690

80

10/50

422232

690

80

10/50

422240

690

80

10/50

422250

690

80

10/50

422263

690

80

10/50

422280

500

120

10/50

422200

500

120

10/50

422215

400

120

10/50

 
Neutral Links
Size: mm (ØxL) Catalogue No. Packing Qty
8 x 31 430000 10/100
10 x 38 431000 10/100
14 x 51 432000 10/50
22 x 58 433000 10/50
 
Power Dissipation (Watts)
IN(A) 8,5 x 31,5 10 x 38 14 x 51 22 x 58

0,5

1,2

1,43

--

--

1

2,0

2,77

3,90

--

2

0,5

0,60

0,90

1,00

4

0,8

0,70

1,00

1,10

6

1,1

0,85

1,15

1,30

8

1,3

0,75

1,00

1,10

10

1,0

1,00

1,30

1,50

12

1,2

1,30

1,70

1,80

16

1,5

1,60

2,00

2,10

20

2,0

2,00

2,50

2,70

25

2,6

2,60

3,30

3,30

32

--

2,90

3,50

3,50

40

--

--

4,75

4,00

50

--

--

4,80

5,50

63

--

--

--

6,90

80

--

--

--

7,80

100

--

--

--

9,00

125

--

--

--

11,4

Size 8,5 x 31,5 10,3 x 38 14,3 x 51 22,2 x 58
A 8,5 10,3 14,3 22,2
B 31,5 38 51 58
C 6,3 10 13 16
D -- -- 8 8
E All dimensions in mm 4 4
 
 
 
Time-Current Characteristics for Class: gG Fuses Cutt-Off Characteristics for: gG Fuses
 
   
   
I2t Characteristics for Class: gG Fuses
 

Fuses are generally suitable for both AC and DC applications. The DC performance of fuses is different, hence AC ratings cannot be used for DC applications.

There is no simple rule that safely converts an AC voltage rating of a fuse to DC voltage rating. For this reason it is necessary to take into account a lot of aspects in order to determine the DC applications. In the DF ELECTRIC Fuses it is necessary to take into account the following considerations:

  • The power dissipations are the same in AC (RMS value) and the DC values.
  • The time current characteristics are the same for DC applications under steady-state conditions.
  • The DC rated voltage and maximum breaking capacity are lower than the AC values (see table below).
  • In some sizes it is necessary to reduce the maximum rated current for DC applications (see table below).

IEC Industrial Cylindrical Fuses Class: gG

Size

Rated Voltages

DC Breaking Capacity

Max. Rated Current for DC

8,5 x 31,5

400VAC 150VDC

3kA

10A

10 X 38

500VAC 250VDC

15kA

16A
14 X 51 500VAC 250VDC 15 kA (250VDC) 32 A
690VAC 440VDC 10 kA (400VDC) 32 A
22 X 58 500VAC 250VDC 15 kA (250VDC) 80 A

690VAC 440VDC

10 kA (400VDC)

80 A
 